What it means¶
Before loading, the host firewall baseline reads the sockets the host listens on (ss) and found one, on a non-loopback address, that no rule admits and that the deployment has not named as closed on purpose. Loading would cut that service without anyone deciding it. Nothing was applied.
Why it happens¶
- the host runs another service beside the peering (a management server, a portal, an exporter)
- a port the deployment means to close is not listed in goat_host_firewall_closed_listeners
What to do¶
One line per step or alternative:
admit it: goat_host_firewall_override: {other-tcp: {ports: [<port>], reason: "<why>"}}
close it on purpose: goat_host_firewall_closed_listeners: ["tcp/<port>"] (or the process name)
Read more¶
Exit code¶
goatbuilder exits with 5.